Boxed HP H5M63A 5.7kVA 208 V 16A Three Phase 27 Outlet Dual Voltage PDU HP P/N 723450-001

Sale!
H5M63A-6
H5M63AH5M63A-5H5M63A-8H5M63A-7H5M63A-6H5M63A-2H5M63A-3H5M63A-4
4.43 out of 5 based on 7 customer ratings
(12 customer reviews)

Original price was: $299.00.Current price is: $49.00.

723450-001 Designed to fit in 36U and taller racks. Support high input voltage (200-240V) Three-Phase Dual Voltage provides twenty-four IEC C13 and three NEMA 5-20R convenience outlets for low voltage equipment in a high voltage rack

702 in stock

Qty Discount - 8+ $99 each |

Product Description

HP 5.7kVA 208 V 16A Three Phase 27 Outlet Dual Voltage BPDU Basic Power Distribution Unit

HP H5M63A Specifications

PDU Output

  • 5.7kVA (Dual Voltage)

Part Number

  • H5M63A

Input Voltage

  • 100-120V/200-208V 3-Phase WYE

Current Maximum

  • 16A per phase

Load Capacity

  • 5764VA @ 208V

Input Connection

  • 8ft(2.4m) cord with attached NEMA L21-20P

Output Circuit Breakers

  • 3 x 20A

Outlet Connections

  • 24 x IEC C13 208VAC , 10 A per outlet
  • 3 x NEMA 5-20R 120VAC, 16A per outlet

Power Cord & Socket

  • NEMA L21-20P PDU Connector
  •  L21-20R Receptacle required

Additional Information

Weight 16 lbs
Dimensions 65 × 9 × 4 in
Manufacturer

HP

Model

H5M63A

UPC

887758272374

Input Voltage

200-208V

Condition

new

Input Connector

NEMA L21-20P

Got something to discuss?


 

12 reviews for Boxed HP H5M63A 5.7kVA 208 V 16A...

  1. 5 out of 5

    Anonymous (verified owner)

    Awesome

  2. 5 out of 5

    Sandeepkumar Jagani

    Do you know how to use this of I have have L6-30r recepticales?

    • Joseph g (store manager)

      L6-30R would be for a two-phase PDU. We use these our self a lot in the past. This PDU is three-phase and will use NEMA L21-20. Consider this… You can always remove the plug and make the connection in a junction box. Wire to Wire! It’s not fancy but it works and it is legal.

  3. 5 out of 5

    Sandeepkumar Jagani

    Joseph; I am sorry to keep posting here. But I need one more confirmation. If I do wire to wire connection, is it safe to use only two phases of the three that goes in to PDU. The 240v will be 180 degrees phase while the three phase will be 120degrees. Will it be safe to operate the PDU just by connecting two phases in PDU input?

    • Joseph g (store manager)

      Hi again, I wouldn’t attempt that. These PDUs are designed for three-phase. They are plenty of two-phases PDU on eBay at a really cheap price. On two phase that would be just fine.

  4. 5 out of 5

    Anil Ali

    Quick question i am looking for the outlet which work with this pdu. I found this will it work.

    • Joseph g (store manager)

      I have to remove your link for security but that is correct. I have also modified our listing to make this connector and receptacle understood for others. > Power Cord & Socket NEMA L21-20P PDU Connector / L21-30R Receptacle required 

  5. 1 out of 5

    solkush (verified owner)

    It says “NEMA L21-20P PDU Connector” as the power cord and then “L21-30R Receptacle required” but the connector won’t fit into the outlet. Is this incorrect? do i really need a L21-20P receptacle? Please explain.

    • Joseph g (store manager)

      It’s a miss print. it should have been L21-20R. Saw them on eBay at $9

  6. 5 out of 5

    rickytr23

    I have l21 30r but the wire I’m using is a 10/4 romex Cable, do I need or should use a 10/5 cable.

  7. 5 out of 5

    Bradley Borne

    How long is the power cable on the PDU?

    • Joseph g (store manager)

      Hi Bradley, 8 foot long